Section 14

Precision and Accuracy Are Not the Same Thing

Written from the class day of September 15 · TEKS P.1C, P.2

In ordinary speech precise and accurate are near-synonyms. In this room they name two different properties, they come apart, and the case where they come apart is the dangerous one — because data that is precise and wrong looks better than data that is accurate and scattered.

The two questions

Precision: do my repeated measurements agree with each other? A statement about spread. It says nothing about truth.

Accuracy: are my measurements close to the true value? A statement about the target. It says nothing about consistency.

The four cases, as they appear in a notebook
CaseThree trials (true value 2.65)MeaningHow you would find out
Precise and accurate2.65, 2.64, 2.66Good instrument, good technique.Compare against a reference.
Precise, not accurate2.20, 2.19, 2.21A consistent offset in every reading.Only by comparing to a reference. The data alone looks excellent.
Accurate, not precise2.40, 2.90, 2.65Sloppy technique, no bias. The average is right.
Neither2.10, 3.40, 2.75Something is wrong with the method itself.

Read the second row again. Those are the tightest three numbers on the table. Handed in, they would look like the best work in the class. They are also the furthest from the truth, and nothing inside that data set can reveal it.

A ruler with the first centimetre snapped off gives beautifully repeatable, uniformly wrong answers all day, and never once looks suspicious.

Two kinds of error, and why the distinction is practical

Random error is scatter. It pushes readings above and below the true value roughly evenly — eye position, air currents, exactly where you judged the estimated digit. It damages precision, and averaging genuinely helps, because the pushes tend to cancel.

Systematic error is bias. It pushes every reading the same direction by roughly the same amount — an unzeroed balance, water left in the cylinder, a thermometer reading two degrees high, a timer with a consistent reaction-time lag. It damages accuracy, and averaging does nothing to it whatsoever. Ten trials give a beautifully precise wrong answer.

That is the payoff, and it tells you what to do: scattered data, take more trials. Tight data that disagrees with the world, stop taking trials and go check the instrument.

Reaction time, which is the physics version

There is one systematic error you will meet constantly in this course and it is worth naming now. When you time something by hand, you start the stopwatch late and stop it late. If the two lags were identical they would cancel — but they are not, because starting on an expected signal is faster than stopping on an event you have to notice.

The result is a consistent bias in every hand-timed measurement you will take. It does not average away. The fixes are real: use a photogate where the timing matters, time ten swings and divide by ten so the fixed lag is spread across ten periods, or measure the bias directly and correct for it.

Notice that all three fixes come from having identified the error as systematic. If you had thought it was scatter, you would have taken twenty trials and got nowhere.

Your rock data, judged both ways

Go back to your August numbers and take one unknown.

Precision first. Largest minus smallest is your range — crude, and perfectly defensible. Three densities within about 0.05 g/mL is tight work with a cylinder. Half a unit apart and something in the volume step is varying between trials.

Accuracy second. Compare your average to the accepted value. Quartz is 2.65 g/mL. Granite runs 2.6 to 2.8 depending on composition, which is itself worth noticing — some materials genuinely do not have one true value, and that is a property of the material rather than a failure of yours.

Then diagnose, which is the actual assignment:

Scattered but centred — something varied between trials. Bubbles on some runs, meniscus read from different heights, rock not fully submerged once.

Tight but off — something was identically wrong every trial. Balance not zeroed. Water carried over from the previous rock. Consistently reading the top of the meniscus rather than the bottom, which inflates every volume by about the same amount and depresses every density.

The second diagnosis exists only because you had a reference to check against. Without one you would have had no way to know, which is exactly why a working lab runs known standards through the same procedure as the unknowns.

"Error" does not mean "mistake"

In physics, error is the difference between your measurement and the true value. It is expected, quantified and reported. It does not mean you did something wrong.

A measurement with no stated error is a weaker claim, not a stronger one, because nobody can tell whether it disagrees with anything. 2.64 g/mL alone says less than 2.64 ± 0.03 g/mL, which tells a reader exactly what would and would not surprise you.

Mistakes are separate — writing the mass in the volume column, misreading 79.6 as 76.9, dropping the rock. Those are blunders. The honest response is to re-run the trial and say so, not to bury it in an average.

Check yourself

  1. Four trials give 3.10, 3.11, 3.09, 3.10 g/mL; the accepted value is 2.70. Precise? Accurate? Most likely cause? Would a fifth trial help?
  2. Why can "accurate but not precise" data be more trustworthy than "precise but not accurate" data, despite looking worse?
  3. You hand-time a pendulum and every period comes out slightly long. Classify the error and give two fixes that would actually work.
Learning standardsP.1C — organise, analyse and make inferences from data, including identifying and classifying sources of error. P.2 — evaluate experimental results, distinguishing random from systematic error.